Outside Glaze with Intermediate Horizontal:
* Design Pressure = +35/-35 PSF
* Maximum DLO at design pressure 46'' x 72''
* Water @ 15 PSF
* Spans up to 8'-0'' with maximum mullion spacing at 48'' on center
* Air infiltration at 6.24 PSF " less than .06 CFM

Inside Glaze without Intermediate Horizontal:
* Design Pressure = +55/-55 PSF
* Maximum DLO at design pressure 46'' x 92''
* Water @ 15 PSF
* Spans up to 8'-0'' with maximum mullion spacing at 48'' on center
* Air infiltration at 6.24 PSF less than .06 CFM

Features Include:
* 2'' x 4 1/2'' Inside glazed for 1'' insulating glass
* Screw-spline joinery using #14 x 1'' spline screws
* Hydraulic Coral-Punch or drill jig fabrication options
* Deep pocket perimeter sections:
* Allows for direct anchor attachment to substrate
* Eliminates drilling access holes and blind caulk seals
* Eliminates flat filler plate at head and wall jambs
* Allows for 1/4'' diameter hex head anchor bolts to substrate
* Fully tested for inside glazing with and without horizontal
* Integral subsill flashing with ''C'' slot for holding sealant